Branch: Kyiv, Baseina St. Intake open now.
02
Session scope
Fault-code read, freeze-frame data and live measured values, taken in that order, in the bay or on the lift. The session closes with a written record, not a verbal opinion.
04 / Diagnostics
Each line pairs a fault code with the value read at the connector, the tolerance taken from the manufacturer's data, and the verdict the technician signed. Readings are logged at reference conditions: coolant 85-95 C, engine at idle unless the row says otherwise.
| Code | Measured | Tolerance | Verdict |
|---|---|---|---|
| P0299Charge pressure below setpoint | 1 320 mbar | 1 550-1 800 mbar | Attention |
| P2181Coolant temperature regulation | 88 C | 85-105 C | Within tolerance |
| U0100Bus voltage drop at CAN splice | 0.02 V | below 0.05 V | Within tolerance |
| B1B02Resting current draw, locked, 60 min | 41 mA | at or below 30 mA | Attention |
Rows are reproduced from closed work orders with owner consent. Plate numbers are masked; part numbers and technician IDs stay on the printed record.
Known limits
A session does not always reveal an intermittent failure that occurs only under load or at a specific operating temperature. That is a limit of the method, not a hidden charge.
Every session is documented: the complaint in the customer's own words, measured values against tolerance, and the conditions the vehicle was tested under. See the measured record on this page for an example.
04 / Intake
Give the plate or VIN and your city. The branch confirms the slot and the labour rate per norm-hour before the vehicle goes on the lift.
Prefer to talk first? Call +380 932 354 1786 or read the full session scope.